Teejet Legacy 6000 Manual Manual de usuario Pagina 72

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 159
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 71
Legacy 6000
98-05053 R2
67
Table 3-5: Product Setup
Item Description
In Use DeneswhethertheControlChannelwillbeusedtoapplyproduct.
Prescription IfusingVariableRateproductapplication,selecttheprescriptionle(.ARM)that
containsinformationforthatchannel.The(.ARM)lemustbeontherootofthePC
Card, and the PC Card must be inserted into the L6K. If not using variable rate, leave
this setting at <None>.
Layer Someprescriptionles(.ARM)cancontainseveralproductsinasinglele.Asingle
productisassociatedwithasinglechannel.Inamultipleproductprescriptionleitis
necessary to establish which product layer is associated with the selected channel. If
thereisonlyoneproductlayerinthe(.ARM)le,thissetupitemisautomaticallysetto
Layer 1 and this page is skipped in the Product Setup wizard process.
ARM Color Allowstheoperatortoselectacolorschemefortheprescriptionlemapshownonthe
Legacy Map page.
Product Product Setup contains a database with approximately 4000 product names and their
associated EPA numbers. Products can be selected from this database. If using a
prescription map (.ARM), product setup automatically extracts the product name from
the (.ARM) product layer or user can enter product name.
Correction Factor Factor for solutions heavier or lighter than water with pressure based applications
(only for Pressure Based liquid applications).
Product Density The density of the product being applied in Granular or NH3 applications (refer to AP-
PENDIX C - NH3 APPLICATION).
Calibration Table Value (e.g.,
Gate Height)
If a Calibration table was established in Channel Setup (refer to CHAPTER 2 - PRIMA-
RY SENSOR), and has been populated either manually or by calibration procedures,
the appropriate values can be selected here for use in the job.
Initial Quantity The initial quantity of the product loaded in the tank, bin, etc.
Rates A - E The ARM software allows 5 preset application rates to be selected.
Product Name Selection
If variable rate product application will not occur, the product being applied can be
selected from the Fieldware Products database. To use variable rate application,
theproductnamecanbeextractedfromanexisting(.ARM)le.
Figure 3-23: Product Selection
New Product
softkey
Enter Name
Favorites softkey
Product database
pick list