Chapter 2 - System Overview38
Table 2-18: Monitor Settings
Settings Description
Input Denesdigitalandanalogsensors.SensorinputsA-Daredigital(owmeterandslot
sensors) and Sensors E-F are analog (pressure). 4-20 mA sensors can only be used on
the Sensor Input E on Gen I CAN systems. Gen II systems can read 4-20 mA and -5V
sensors on Inputs E and F.
Sensor Name Labels a particular sensor or monitor. This information is not stored in the Channel and
is used for messaging to the user only.
Calibration # Thecalibrationnumberinunitsspecied(FlowmeterandRotationsensorsonly).This
numberistypicallyfoundonthesensor.Physicalcalibrationwillfurtherne-tunethis
number.
Table 2-19: Monitor Sub-Settings
Settings Description
Alarm Units Pressure psi
Flowmeter gal/min
Shaft rpm
Min. Alarm Minimum alarm limit.
Max. Alarm Maximum alarm limit.
Alarm Delay Duration an alarm condition exists before triggering an alarm.
Alarm Status Off - disabled
Low - sensor state goes low to trigger alarm. Contact the sensor or machine supplier
for this information.
High - sensor state goes high to trigger alarm. Contact the sensor or machine supplier
for this information.
Channel Setup Completion
ThenalpageintheChannelSetupprocess is the Finish page. From the Fin-
ishpage,theoperatorcanreviewandconrmallpreviously-selectedoptionsby
pressing the Review Settingssoftkey.Theoptionscanalsobesavedtoalefor
later use by pressing the Save to File softkey (refer to CHAPTER 2 - SAVING
CHANNEL SETUP for additional information).
Channel settings can be applied directly to the channel without saving them by se-
lecting the Send to Channel softkey. The Channel will use the changes made dur-
ing application. If a new application is needed and the channel favorite or settings
have not been saved, all prior settings will be lost. Saving the channel favorites
takes very little time and can save time in the future.
Review Settings
softkey (F2)
Send to Channel
softkey (F6)
Save to File
softkey (F7)