APPENDIX C - NH3 APPLICATION
When using NH3 mode, review the following settings to ensure the Cal # and
Density have been correctly entered. The Cal # is located in Channel Setup under
“Primary Sensor, Tools”. The Density value is accessed from the ARM Launcher
page in Product Setup.
NH3 Application Cal#
For all NH3 applications, the Cal # units should be entered in Pulses / Gallon. The
Cal # units DO NOT change even if the displayed units are in (LBS of NH3 / acre)
or (LBS Actual N / acre).
Density for NH3 and Actual N
Density determines the units of applied and displayed rate (lbs of NH3 / acre or lbs
of actual N / acre) during application. If application and display rate in lbs of NH3 /
acre is desired, enter a density of lbs of NH3 / gal. If application and display rate in
lbs of Actual N / acre is desired, enter a density of lbs of Actual N / gal.
NOTE: Temperature affects the Density. The following chart provides a cor-
rected value. Use the temperature or tank pressure column to deter-
mine the correct density.
Example: The display of pounds of actual N / acre is desired. If the temperature
is 65
o
F, the density would be entered during Product Setup as 4.19 lbs
of actual N / per gal.
NH3 is 82% Actual N by weight
1gal NH3 @ 60oF = 5.15lbs x .82 =
4.22lbs of Actual N / 1 gal of NH3
Vista de pagina 157
1 2 ... 153 154 155 156 157 158 159

Comentarios a estos manuales

Sin comentarios