Chapter 5 - System Tools114
Channels
The status of each channel on the CAN Bus can be viewed under Device Manager
- Channels. Each channel is assigned a Serial Number and an ID Number. One of
the channels must be assigned as the base channel. The base channel will receive
the ground speed input if provided by other than a GPS receiver.
Figure 5-5: Channels Setup
Table 5-4: Channels Settings
Softkey Description
Module Reset. Resets all modules to factory default or each channel can be reset.
UpdateFlash.Updatesthemodule’sash.SoftwaremustbeloadedonthePCCard
for the module to be updated.
Information. Displays general module information, serial numbers, and software ver-
sion.
Channel Setup
When using a Dual Control Module (DCM), the operator has the ability to use two
channels on each DCM connected to the CAN Bus. Each channel must be turned
on (YES) and a unique ID number must be assigned if the channel will be used.
1. Highlight the desired channel in the center of the screen using the Arrow
keys and press the Enter button.
2. Turn the channel on (YES) and set an ID number. Typically channel one
will be set to ID 1.
Arrow keys
Enter button