Legacy 6000
98-05053 R2
35
input lines for sensors are established on the Sensor Settings page.
Secondary Sensor options include:
Flowmeter
•
Pressure Digital•
Pressure Analog•
Granular•
Shaft•
Injection•
To access the sub-settings, locate the two Sub-Settings softkeys on the right side
of the screen. Use the two softkeys to toggle between the screens. Refer to Table
2-16 for a description of the sub-settings. When the primary settings and param-
eters have been selected, press the Forward Arrow softkey to advance to the next
Channel Setup page.
Figure 2-29: Secondary Sensor/Sub-Settings
Table 2-16: Secondary Sensor Sub-Settings
Settings Description
Input Denesdigitalandanalogsensors.SensorinputsA-Daredigital(Flowmeterand
slot sensors) and sensors E-F are analog (pressure).
Sensor Name Used to label a particular sensor or monitor. This information is not stored in the
Channel and is used for messaging to the user only.
Dual Warning% Denesthemaximumacceptable%differencebetweentheprimaryandsecondary
sensor outputs before the operator is warned.
Dual Warning Delay Denesthetimethattheprimaryandsecondarysensoroutputscanexceedthe
dual warning % before initiating the alarm.
Forward Arrow
softkey (F6)
Initial-Settings
softkey (F9)
Sub-Settings
softkey (F10)