31
98-05204 R1 UK
OVERVIEWSETUPAPPENDIX GETTING STARTEDOPERATION
ISOBUS Job Computer : IC18 Sprayer
BOOM SECTIONS
Boom Sections displays the active and inactive boom sections as well as if they are on (spray is blue) or off
(spray is gray).
Figure 4-9: Boom Sections
Cnt 1
0.0 0
0 l
0
bar
0.00 ha
1311
l/hakm/h
The color on the boom sections indicates the color of the selected nozzle type.
Established Nozzle Sizes and Colors
Size Color Size Color
01 Orange 05 Brown
015 Green 06 Grey
02 Yellow 08 White
025 Purple 10 Light Blue
03 Blue 15 Light Green
04 Red 20 Black
On/O Sections from the Left or Right
When a switchbox is not connected for boom section control, booms sections are
controlled using the Boom Sections On/Off Keys.
Without Switchbox
Figure 4-10: Left Off
Cnt 1
0.0 16.5
0 l
0
bar
0.00 ha
1311
l/hakm/h
Cnt 1
0.0 16.5
0 l
0
bar
0.00 ha
1311
l/hakm/h
Figure 4-11: Right Off
Cnt 1
0.0 16.5
0 l
0
bar
0.00 ha
1311
l/hakm/h
Cnt 1
0.0 16.5
0 l
0
bar
0.00 ha
1311
l/hakm/h
• To adjust the sections on the left, press the LEFT BOOM SECTIONS ON/OFF
KEYS .
• To adjust the sections on the right, press the RIGHT BOOM SECTIONS ON/
OFF KEYS .
With Switchbox
If a switchbox is being used to control the boom sections, boom sections will be
controlled by the switchbox.
Figure 4-12: Operations Screen With Switchbox
Cnt 1
0.0 0
0 l
0
bar
0.00 ha
1311
l/hakm/h