13
98-05204 R1 UK
OVERVIEWSETUPAPPENDIX GETTING STARTEDOPERATION
ISOBUS Job Computer : IC18 Sprayer
JOB PARAMETERS
Job Parameters congures application settings. Options include Active Trip Counter, Preset Application Rates and Nozzle.
MAIN SETUP MODE MENU STRUCTURE
| | | | | |
Counters Job Parameters Machine User Interface Communication Help
Figure 3-11: Job Parameters
1. From the Main Setup Screen , select JOB PARAMETERS.
NOTE: Settings are NOT automatically saved when selected. The
ACCEPT KEY must be selected to save the setting. Select the
ESCAPE KEY to escape without saving settings and return to
the previous menu.
Active Trip Counter
Active Trip Counter selects one of up to ten (10) active trip counters to view the
desired trip information. The trip that is “active” is displayed/active on the Operation
Screen.
• To select the Active Trip Counter, use the number pad or slide bar.
NOTE: The selected trip counter will have all data modified (added too) when
additional operations are activated. If current trip counter is not cleared,
the new data will be added to the existing data.
Preset Application Rates
Preset Application Rates dene up to ve (5) target rates of product being applied per hectare/acre. These settings will set the same for all
active trips. Target rates set to "0.0" will not be in included in the TOGGLE PRESET TARGET RATE options on the Operation Screen
or Home Screen.
• To select the Application Rate, use the number pad or slide bar.
Nozzle
Nozzle selects the nozzle type. This setting will set the same for all active trips. The ve (5) available nozzle types are preset under
Main --
>
Machine --
>
Implement Parameters --
>
Nozzle Preset Setup.
• To select the Nozzle type, select an option from the drop down menu or use the UP/DOWN ARROWS to highlight the option.