1-2
TASC 6100
98-05018
R2
CE & STANDARD V ERSION
INC / DEC SWITCH
The Increase/Decrease (INC/DEC) switch (see #3 in
Fig. 1-1) is used, in both the OPERATE and SET-UP
modes, to adjust the values appearing in the display.
BOOM SECTION “ON/OFF” INDICATORS
The boom section On/Off indicators (see #5 in Fig. 1-
1) indicate which boom sections the operator has
selected. When a boom is turned on, its indicator is lit.
There are a maximum of nine boom sections available.
RATE SWITCH
The Rate Selector switch (see #6 in Fig. 1-1) is a three
position switch that allows the operator to select
either a pre-selected standard rate, an alternate rate, or
stop the application.
DISPLAY SELECTOR SWITCH
The Display Selector (see #4, Fig. 1-1) is used to
choose which of the console functions is displayed on
the screen and is available for setting by the operator.
Display Selector - Operate Mode (Liquid)
(See Fig. 1-2)
Speed: The current vehicle speed.
Area: Area Accumulator #1. The total area treated
since the counter was last reset.*
Fan RPM: Not used in liquid mode.
Product Vol: Amount of product aboard the vehicle.
Value counts down as the product is applied and
alarm sounds when 10 % of the full load is left.**