2-11
98-05018
R2
CE & StandardVersion
TASC 6100
Setup
& Cal.
Low Product Alarm
The Low Product Alarm alerts the operator when the
Product Vol., displayed on the console, reads 10% of the
Full Load Capacity. The console beeps for three seconds
and displays the message "LO - PROD". Console
control functions are not affected by this alarm. To
disable the alarm, do not recall the Full Load Capacity.
RESETTING ACCUMULATORS
U
se the following method to reset the Area,
Distance, and Total Applied accumulators to
zero:
A. Set the Console to the following switch settings:
1. Power ON
2. Mode Selector OPERATE
3. Display Selector Area / Total
Applied /Distance
B. Hold the INC./DEC. Switch to DEC. until the display
reads zero (Approximately 3 sec.)
NOTE: There is also an Area/SET-UP accumulator.
OPERATING UNDER EXTERNAL RATE COMMANDS
W
hen the TASC 6100 console is operating under
external rate commands, it must be connected
to the computer running the field mapping
program through a Mid-Tech Data Link. Minimum and
maximum anticipated rates must be programmed into the
Standard Rate and Alt.-Rate positions of the Rate switch
respectively and the Rate switch must be placed in the
Alt.-Rate position. The instructions, received with the
Data Link, explains in more detail how to set up the
TASC 6100 and Data Link.
DISPLAY SELECTOR
Speed
Area Impl. Width
Distance
Test
Speed
PSI/Prime
Total Applied
Application Rate
OFF SET- UP DEC.
ON
OPERATE INC.
Scan
Product Vol.
Fan RPM
BOOMS
123456789
% Rate
A-1
A-2
A-3
B