Pressure Sensor High/Low Calibration
The pressure sensor's Zero and High Set Point values must
be set to match the readings from your manual pressure
gauge. To do this, follow the procedure below.
Setting The Zero Set Point
A. Set the console to the following positions;
1. Power switch ON
2. Mode Selector OPERATE
3. Display Selector switch PSI/Prime
4. At least one Boom switch ON
(to release any trapped pressure)
5. Master switch ON
6. GSO switch OFF
7. Supply Pump OFF
8. Zero ground speed (vehicle not moving)
NOTE: Before adjusting the Zero Set Point, make sure
there is no pressure in the boom. It may be necessary to
loosen the diaphragm check valves on the boom to
achieve this.
B. Hold INC./DEC. switch to DEC. until console
reads PSi 0 (br 0).
Setting The High Set Point
A. Set the console to the following positions;
1. Power Switch ON
2. Mode Selector OPERATE
3. Display Selector Switch PSI/Prime
4. Rate Switch Standard Rate
5. Master Switch ON
6. Supply Pump ON
7. Zero ground speed (Vehicle not moving)
B. Hold INC./DEC. switch to INC. for about 3
seconds. Display will read "OPEN". Release the INC
as soon as the OPEN message appears. Slowly
increase the engine RPM to adjust the pressure
reading, on the pressure gauge, to a maximum of no
A-7
MT 1000
MPH / KPH
A-8
A-6
MT 1000
MPH / KPH
A-7
MASTER
ON
OFF
MI
A-5
DISPLAY SELECTOR
Speed
Area Impl. Width
Distance
Test
Speed
PSI/Prime
Total Applied
Application Rate
OFF SET- UP DEC.
ON
OPERATE INC.
Scan
Product Vol.
Fan RPM
BOOMS
123456789
% Rate
A-1
A-2
A-3
B
Alt.-Rate
Standard Rate
OFF
A-4
BOOM CONTROL SWITCHES
MASTER
ON
OFF
OFF
GSO
AUTO
MIDWEST TECHNOLOGIES, INC.
MID-TECH
®
A-4
A-5
A-6
DISPLAY SELECTOR
Speed
Area Impl. Width
Distance
Test
Speed
PSI/Prime
Total Applied
Application Rate
OFF SET- UP DEC.
ON
OPERATE INC.
Scan
Product Vol.
Fan RPM
BOOMS
1 23456789
% Rate
A-1
A-2
A-3
B
A-4
Vista de pagina 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 85 86

Comentarios a estos manuales

Sin comentarios