Teejet 844-AB Sprayer Control Manual de usuario Pagina 1

Busca en linea o descarga Manual de usuario para Ordenadores Teejet 844-AB Sprayer Control. TeeJet 844-AB Sprayer Control User Manual [pl] [en] [cs] [de] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - SPRAYER CONTROL

844-AB SPRAYER CONTROL USER GUIDE MANUALFor use with software version 4.02.

Pagina 2 - Limitation of liability

8www.teejet.com844-ABPress the Programme key. The console will ask for the volume that was sprayed. Use the Plus or Minus keys to adjust the val

Pagina 3 - Table of Contents

998-70007-EN R4844-ABSpeed sensor calibrationThe speed sensor must be calibrated in order to provide the proper speed and area readings. The value is

Pagina 4 - CHAPTER 8 - FEATURES 18

10www.teejet.com844-ABAutomatic calibrationTo automatically calibrate the radar speed sensor, mark a distance of exactly 100 metres. Press the Plus

Pagina 5 - CHAPTER 1 - INTRODUCTION

1198-70007-EN R4844-ABReference ow rate per sectionAB mode – The ow rate for each section of the sprayer must be input into the 844-AB console so th

Pagina 6 - CHAPTER 3 - OEM SETUP

12www.teejet.com844-ABRegulating valve response timeOperating conditions may require a higher or lower response speed for the regulating valve. To cha

Pagina 7

1398-70007-EN R4844-ABDensity (Liquid specic gravity)The default value of “1.00” corresponds with the specic gravity of water and is correct for mos

Pagina 8 - CHAPTER 4 - SYSTEM SETUP

14www.teejet.com844-ABCHAPTER 5 - SWATH WIDTH PRESETSThe 844-AB can be programmed with up to 6 swath widths. This allows the operator to easily change

Pagina 9 - Flow meter impulses

1598-70007-EN R4844-ABCHAPTER 6 - APPLICATION SETUPApplication Setup mode contains the most frequently changed setup parameters (target application ra

Pagina 10 - Automatic calibration

16www.teejet.com844-ABAdjust pressureIf an approximate operating pressure is known, use the Plus or Minus keys to adjust the value. The 844-AB wil

Pagina 11 - Speed sensor calibration

1798-70007-EN R4844-ABCHAPTER 7 - OPERATIONSBefore operating, check connections related to the Sprayer control assembly. The sensors should be checked

Pagina 12 - Simulated ground speed

Copyrights© 2013 TeeJet Technologies. All rights reserved. No part of this document or the computer programmes described in it may be reproduced, copi

Pagina 13 - Next section

18www.teejet.com844-ABCHAPTER 8 - FEATURESBoost modeIncreased or decreased chemical application may be required during certain areas of application. T

Pagina 14 - Minimum pressure setting

1998-70007-EN R4844-ABNo ow alarmIf the 844-AB stops receiving impulses from the ow meter, the turbine symbol will ash at the top of the display. T

Pagina 17 - CHAPTER 6 - APPLICATION SETUP

TeeJet AabybroMølhavevej 2DK 9440 AabybroDanmarkwww.teejet.com844AB SPRAYER CONTROLUSER GUIDE MANUAL98-70007-EN R4 English/International © TeeJet Tech

Pagina 18 - Adjust speed

198-70007-EN R4844-ABTable of ContentsCHAPTER 1 - INTRODUCTION 3Power on the console ...

Pagina 19 - CHAPTER 7 - OPERATIONS

2www.teejet.com844-ABFaces per section setting (HC mode only) ...

Pagina 20 - CHAPTER 8 - FEATURES

398-70007-EN R4844-ABCHAPTER 1 - INTRODUCTIONThis user guide provides information for software version 4.02.Make sure that all hardware components are

Pagina 21 - 98-70007-EN R4

4www.teejet.com844-ABCHAPTER 2 - APPLICATION MODE The 844-AB gives the possibility of working in two different ways to t the application. Therefore,

Pagina 22

598-70007-EN R4844-ABMinimum voltageThis will determine the minimum voltage that can be applied to the regulation valve. If too low, the valve won’t 

Pagina 23

6www.teejet.com844-ABMemory optionThis feature enables the user counters. Select NO to disable this feature or YES to enable it.Figure 14: Memory opti

Pagina 24

798-70007-EN R4844-ABReset to defaultIf units of measurement changes were made, the console will display a message asking if programme parameters shou

Comentarios a estos manuales

Sin comentarios