Teejet TASC-6500 Manual de usuario

Busca en linea o descarga Manual de usuario para Ordenadores Teejet TASC-6500. TeeJet TASC-6500 User Manual [en] [pl] [cs] [de] Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 50
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
I
Midwest Technologies, Inc. of Illinois
Springfield, IL 62703
TASC 6200/6500
TOTAL APPLICATION
CONTROL SYSTEM
USER GUIDE
PN - 98-05019
Rev - 1
TASC-6500
CHEMICAL APPLICATORS
ON
OFF
Alt.-
Rate
%Rate
DISPLAY SELECTOR
Speed
Area
Width
Distance
Vol. Applied
Test
Speed
Fan RPM
Vol. Applied
Appl. Rate
Appl. Rate
OFF SET- UP DEC.
ON OPERATE INC.
123456789
BOOMS
Scan
MID-TECH
MIDWEST TECHNOLOGIES, INC.
RATE CONTROL CHANNELS
L & CHEMICALS CARRIER
.
-Ac
Flow
RATE
Gal./
®
123
L
C
MID-TECH
MIDWEST TECHNOLOGIES, INC.
CE & STANDARD VERSION
Vista de pagina 0
1 2 3 4 5 6 ... 49 50

Indice de contenidos

Pagina 1 - TASC 6200/6500

IMidwest Technologies, Inc. of IllinoisSpringfield, IL 62703TASC 6200/6500TOTAL APPLICATION CONTROL SYSTEMUSER GUIDEPN - 98-05019Rev - 1TASC-6500CHEM

Pagina 2

1-698-05019Rev- 1CE & STANDARD VERSIONTASC 6200/65001.9 GROUND SPEED OVERRIDE SWITCHAn optional ground speed override (GSO) switch can be used to

Pagina 3

2-198-05019Rev- 1TASC 6200/6500CE & STANDARD VERSION2.0 CALIBRATION AND SET UPIn order to control accurately, the TASC console requires certain i

Pagina 4

2-298-05019Rev- 1CE & STANDARD VERSIONTASC 6200/6500Power OFFMode selector SET-UPDisplay selector DISTANCEB. Turn the rate selector switches, for

Pagina 5

2-398-05019Rev- 1TASC 6200/6500CE & STANDARD VERSION2.4 SETTING APPLICATION RATESEach TASC channel can maintain a constant, preset application ra

Pagina 6 - CE & STANDARD VERSION

2-498-05019Rev- 1CE & STANDARD VERSIONTASC 6200/6500B. Use the INC/DEC switch to set the desired rate. Example, 64.0 for 64 Fluid Oz. (2 qts.) per

Pagina 7 - VERSION

2-598-05019Rev- 1TASC 6200/6500CE & STANDARD VERSIONbooms are turned OFF. HOLD is useful in maintaining pressure to the boom shut-off valves on a

Pagina 8

2-698-05019Rev- 1CE & STANDARD VERSIONTASC 6200/65002.9 SETTING BOOM WIDTHSTASC automatically compensates for changes in the swath width, caused

Pagina 9

2-798-05019Rev- 1TASC 6200/6500CE & STANDARD VERSIONplace to maneuver the vehicle. The longer the distance, the more accurate the test.C. Drive to

Pagina 10 - TANDARD VERSION

2-898-05019Rev- 1CE & STANDARD VERSIONTASC 6200/6500C. Set an application rate similar to one you would use in the field (see 2.4.1). Zero the acc

Pagina 11

2-998-05019Rev- 1TASC 6200/6500CE & STANDARD VERSIONpulses per gallon. If the system uses a flow meter to sense the liquid flow, use the following

Pagina 12

CHANGES DATE REVISION # DESCRIPTION SW VERSION05/15/00 1 New Manual - CE Console 2.62Mid-Tech, Auto-Range, & TASC are

Pagina 13

2-1098-05019Rev- 1CE & STANDARD VERSIONTASC 6200/65002.13 CALIBRATING PRODUCTS 1,2 AND 3 (TASC 6500 ONLY)Channels 1,2 or 3 can be used as either

Pagina 14

2-1198-05019Rev- 1TASC 6200/6500CE & STANDARD VERSIONA. Use the following switch settings to start the calibration:Power ONMode selector SET-UPDis

Pagina 15

2-1298-05019Rev- 1CE & STANDARD VERSIONTASC 6200/6500A. Use the following switch settings to start the calibration (Be sure to set the proper prod

Pagina 16

2-1398-05019Rev- 1TASC 6200/6500CE & STANDARD VERSIONA. Use the following switch settings to adjust the Auto Power down time:Power OFFMode selecto

Pagina 17

2-1498-05019Rev- 1CE & STANDARD VERSIONTASC 6200/6500This page purposely left blank

Pagina 18

3-198-05019Rev- 1TASC 6200/6500CE & STANDARD VERSIONTASC-6500CHEMICAL APPLICATORS ONOFFAlt.-Rate%RateDISPLAY SELECTORSpeedAreaWidthDistance Vol. A

Pagina 19

3-298-05019Rev- 1CE & STANDARD VERSIONTASC 6200/65003.1.8 STOP APPLYINGReaching the end of the field, turn the booms OFF. The application stops

Pagina 20

3-398-05019Rev- 1TASC 6200/6500CE & STANDARD VERSIONThe programmed rates and alternate rates can be viewed with the vehicle stopped, booms OFF, an

Pagina 21

3-498-05019Rev- 1CE & STANDARD VERSIONTASC 6200/65003.6 MANUAL OVERRIDE OF CONTROL VALVESometimes it is necessary to manually override the co

Pagina 22

4-198-05019Rev- 1TASC 6200/6500CE & STANDARD VERSION4.0 MAINTENANCEMaintenance is a matter of common sense. Here are a few tips.4.1 FLUSHING AND C

Pagina 23

IIICE & STANDARD VERSIONTASC 6200/650098-05019Rev- 1TABLE OF CONTENTS ...

Pagina 24

4-298-05019Rev- 1CE & STANDARD VERSIONTASC 6200/65004.3 GROUND SPEED SENSOR4.3.1 WHEEL SENSORCheck the sensor daily for loose or bent fittings. Mu

Pagina 25

4-398-05019Rev- 1TASC 6200/6500CE & STANDARD VERSION4.7 ROTATIONAL SENSORSPeriodically check rotational sensors to make sure that they are secured

Pagina 26

4-498-05019Rev- 1CE & STANDARD VERSIONTASC 6200/6500BE CAREFUL THAT WATER OR SEDIMENT IS NOT TRAPPED IN THE INJECTION PUMP, PAR-TICULARLY IN COLD

Pagina 27

5-198-05019Rev- 1TASC 6200/6500CE & STANDARD VERSION ERROR CODE CAUSE REMEDY5.0 TASC ERROR MESSAGES, COMMON CONDITIONS A

Pagina 28

5-298-05019Rev- 1CE & STANDARD VERSIONTASC 6200/6500Err 1PUMP-1,2, 3Granular bins(Cont.)Err 1PUMP-1,2, 3Liquid pumpsErr 2Pump 1, 2, 3(Flashing &qu

Pagina 29

5-398-05019Rev- 1TASC 6200/6500CE & STANDARD VERSIONErr 3PUMP-L(Cont.)Err 3PUMP-C, L, 1, 2,3(GranularProduct)(Shuts downsystem after about15 secon

Pagina 30

5-498-05019Rev- 1CE & STANDARD VERSIONTASC 6200/6500TASC ERROR MESSAGES, COMMON CONDITIONS AND SOLUTIONSFIRST Check the battery connections, this

Pagina 31

5-598-05019Rev- 1TASC 6200/6500CE & STANDARD VERSIONCheck, at the valve connector, for the propervoltages during the OPEN and CLOSE commandsto the

Pagina 32

5-698-05019Rev- 1CE & STANDARD VERSIONTASC 6200/6500This page purposely left blank

Pagina 33

6-198-05019Rev- 1TASC 6200/6500CE & STANDARD VERSION6.0 EMERGENCY OPERATIONSMIDWEST TECHNOLOGIES has gone to great lengths to make the TASC Syste

Pagina 34

IVCE & STANDARD VERSIONTASC 6200/650098-0501 Rev- 13.0 OPERATION...

Pagina 35

6-298-0501 Rev- 1CE & STANDARD VERSIONTASC 6200/6500B. Remove the fuse for the flow control valve at the cable disconnect. If the valve has failed

Pagina 36

6-398-05019Rev- 1TASC 6200/6500CE & STANDARD VERSION6.4 APPLICATION RATE SENSOR FAILURE (GRANULAR APPLICATION)The TASC Spreader System, suffering

Pagina 37

6-498-0501 Rev- 1CE & STANDARD VERSIONTASC 6200/6500This page purposely left blank

Pagina 38

A-198-05019Rev- 1TASC 6200/6500CE & STANDARD VERSIONA.0 APPENDIXAppendix-A

Pagina 39

A-298-05019Rev- 1CE & STANDARD VERSIONTASC 6200/6500A.1 TASC 6500 SYSTEM DRAWINGTASC 6500GRANULAR / LIQUID CONTROLLERCarrier PumpBoom Valves(Up t

Pagina 40

A-398-05019Rev- 1TASC 6200/6500CE & STANDARD VERSIONA.2 TASC 6500 SYSTEM DIAGRAM+-BATTERYINJECTIONPUMP312TASC 6500114-0005123FANBOOM INTERFACECHA

Pagina 41

A-498-05019Rev- 1CE & STANDARD VERSIONTASC 6200/6500(See illustration below)TASC uses the inherent capacitance of the vehicle battery to protect t

Pagina 42

A-598-05019Rev- 1TASC 6200/6500CE & STANDARD VERSIONCARRIER RELATED, (Liquid):Noz. Press. = [(Rate x Speed x Noz.Spacing) / (GPM40 x 939.2)]2Wher

Pagina 43 - Appendix-A

A-698-05019Rev- 1CE & STANDARD VERSIONTASC 6200/65001/8 Pint = 2 Fluid Ounces1/4 Pint = 4 Fluid Ounces1/3 Pint = 5.33 Fluid Ounces1/2 Pint = 8 Flu

Pagina 44

A-798-05019Rev- 1TASC 6200/6500CE & STANDARD VERSIONMiscellaneous Conversion factorsU.S. to Metric Metric to U.S.1 Acre = 0.405 Hectares 1 Hectare

Pagina 45 - TASC 6500 Combo

1-198-05019Rev- 1CE & STANDARD VERSIONTASC 6200/6500INTRODUCING TASC FOR THE NEW GENERATION APPLICATORSThe TASC 6500 is a five channel controller.

Pagina 46 - CAUTION !

A-898-05019Rev- 1CE & STANDARD VERSIONTASC 6200/6500This page purposely left blank

Pagina 47

1-298-05019Rev- 1CE & STANDARD VERSIONTASC 6200/65001.0 SWITCHES AND CONTROLSThe figure below shows the switches and displays on the TASC 6500 Con

Pagina 48

1-398-05019Rev- 1CE & STANDARD VERSIONTASC 6200/65001.4.1 DISPLAY SELECTOR FUNCTIONS-OPERATE MODETASC-6500CHEMICAL APPLICATORS ONOFFAlt.-Rate1234

Pagina 49

1-498-05019Rev- 1CE & STANDARD VERSIONTASC 6200/65001.4.2 DISPLAY SELECTOR FUNCTIONS-SET-UP MODETASC-6500CHEMICAL APPLICATORS ONOFFAlt.-Rate123456

Pagina 50

1-598-05019Rev- 1CE & STANDARD VERSIONTASC 6200/65001.5 BOOM SECTION "ON/OFF" INDICATORSThe boom section on/off indicators show which bo

Modelos relacionados TASC-6200

Comentarios a estos manuales

Sin comentarios